Audio speaker placement planner For stand-mounted speakers only

Library of speakers and subs for professional AV, hire and event production

All speakers

Electro-Voice ZLX-12P G2

A powered full-range top, 1 x 12" LF + 1 x 1.4" HF compression driver. The figures below have been checked against the datasheet.

Place it in the planner

Specifications used

Maximum level127 dB at 1 m
Power1000 W (rated power as printed (type not specified))
Coverage90° horizontal × 60° vertical
Frequency range48 Hz to 20000 Hz (-10 dB range from the datasheet; the product page prints the -3 dB response as 54 Hz to 18.5 kHz and shows no value in its -10 dB row.)
Weight14.82 kg
Size (w × h × d)356.2 × 621.1 × 356 mm
SourceManufacturer page (2026-10-10)

How the level was stated. Printed as max SPL at 1 m; the datasheet text I read gave no footnote conditions for this figure.

Coverage definition. Printed as angular range H x V; the datasheet does not define the angle (no -6 dB statement).

Notes. Datasheet V1 Jan 2024. No sensitivity printed. No built-in pole socket listed; only an optional BRKT-POLE-L bracket, so poleMount left out. Three downloads (Japanese, German, English-labelled) agree on the figures.

Coverage shape

Horizontal: 90° (seen from above)
Vertical: 60° (seen from the side)

What the figures mean at distance

Taking 127 dB at 1 m on axis and the free-field rule of 6 dB lost per doubling of distance, this is the most the speaker can reach and how wide and high its nominal coverage is at each distance. A real room adds reflections, and a speaker is not normally run at its maximum.

DistanceLevel on axisCoverage widthCoverage height
2 m121.0 dB4.0 m2.3 m
5 m113.0 dB10.0 m5.8 m
10 m107.0 dB20.0 m11.5 m
15 m103.5 dB30.0 m17.3 m
20 m101.0 dB40.0 m23.1 m

See level and distance and coverage angles for how these are worked out.

Planning estimate only. The calculation ignores reverberation, reflections and room modes. See terms and disclaimer.