NEXO P12 (passive)

A passive full-range top, 1 x 12" coaxial LF + 3" HF. The figures below have been checked against the datasheet.

Place it in the planner

Specifications used

Maximum level138 dB peak at 1 m
Sensitivity107 dB at 1 W, 1 m
Power1270 W (recommended power 800 to 1270 W into 8 ohm (upper figure, from P+ brochure))
Coverage60° horizontal × 60° vertical
Frequency range60 Hz to 20000 Hz (-6 dB; no +/- tolerance printed)
Weight20 kg
Size (w × h × d)432 × 534 × 314 mm
Pole socketYes
SourceManufacturer page (2026-10-10)

How the level was stated. Printed as Peak SPL at 1 m (passive mode); noise type and crest factor not stated.

Coverage definition. Default HF dispersion 60x60 (same in both modes). Optional flanges: 90x40 flange, or 60~100x40 with PS flange. Page does not label axes or define the -dB level; for the non-square options the horizontal/vertical assignment is not stated.

Notes. Pole socket: touring version handles hold a 35 mm pole stand adapter (install version has no handles). Switchable passive/active on Touring and TIS versions; install version passive only. Dimensions: datasheet and brochure table print H x W x D 534 x 432 x 314; brochure body text gives 432 wide x 531 high x 317 deep. Datasheet v1.3 prints no sensitivity or watt rating (sensitivity and power taken from brochure).

Coverage shape

Horizontal: 60° (seen from above)
Vertical: 60° (seen from the side)

What the figures mean at distance

Taking 138 dB at 1 m on axis and the free-field rule of 6 dB lost per doubling of distance, this is the most the speaker can reach and how wide and high its nominal coverage is at each distance. A real room adds reflections, and a speaker is not normally run at its maximum.

DistanceLevel on axisCoverage widthCoverage height
2 m132.0 dB2.3 m2.3 m
5 m124.0 dB5.8 m5.8 m
10 m118.0 dB11.5 m11.5 m
15 m114.5 dB17.3 m17.3 m
20 m112.0 dB23.1 m23.1 m

See level and distance and coverage angles for how these are worked out.

Planning estimate only. The calculation ignores reverberation, reflections and room modes. See terms and disclaimer.